Cabelcon F-6-TD Self Install 4.9 NiTin with TrueDrop connector is the successor of the F-56 Self Install 4.9 (EAN 5707957074416, HAN 99909643-01). Assembly is possible without special tools and is suitable for many RG6 coaxial cables with a diameter of 7 mm and a dielectric with a diameter of 4.6 mm.


Item specifics
Item no. 99909631-04 
Connector type: F-6-TD SELF INSTALL 4.9 NiTin
Frequency Range: 0.3 - 3000 MHz
Impedance (Nom.): 75 Ohm
Transfer Impedance (CoMeT) Class A++ ;  <0.9 mΩ/m @ 5-30MHz ; <0.27 mΩ/item @ 5-30MHz
Screening Attenuation(CoMeT) Class A++: >105 dB @ 30-1000MHz ; > 95 dB @ 1000-2000MHz ; >85 dB @ 2000-3000MHz
Temperature: Installing -5° to +50° C ; Operating -40° to +70° C ; Storing -40° to +70° C
Sealing Test: (IEC IP-code) IP X8 30 meter / 8 hours
Plating: Body Parts Nitin
Torsional Strength: (Connector / Cable) *NATM

*Not Able To Measure(NATM): The cable starts to twist without the connector loosing its grip. 
Tensile strength can be limited by the strength of the cable. Please refer to the cable data. 



Step 1
Strip the cable to obtain the following stripping
A = 6,5mm (outer conductor)
B = 6,5-8,0mm (inner conductor)
For “Quad shield”, “Tri shield” and “Super shield”
cables: Remove the outer braid and foil, only Leave the
inner foil and inner braid, inner foil must be attached to
dielectric and make sure, it is smooth and undamaged.
Clean the cable inner and outer conductor with a
conductor cleaner or any other appropriate equipment.
For your safety and best results Cabelcon’s pre-adjusted
Cable Stripper is recommended. Please read the
instructions for use, supplied with the tool.

Step 2
Verify stripped dimensions by using cutting guide on
the connector.

Step 3
optional option, press connector support sleeve back
into connector, with light pressure for click, it will make
cable installation easier (step 5).
Step 4

Brush / fold exposed braid back over jacket by using a
stripping tool brush (if available) or any other
nonmetallic brush.
Step 5

Push the connector over the foil, allow the support
sleeve to slide between the foil and braid. Press and
turn until the dielectric is flush with the support
mandrel face. For better connector and cable grip,
Cabelcon’s connector mounting and cable rubber grip
tool can be used.

Step 6
Compress the connector by tightening the connector
onto the F female port.